Categories

Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
  • Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount
The PDUMH32HVATNET 7.4kW Single-Phase 230V ATS/Switched PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard racks and features 18 switched outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.



Dual 3-meter input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 230V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.



Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Supports user-programmable startup of outlets in any order or interval to ensure network items are turned on in the proper sequence and reliably discovered. Digital LED display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity with the optional temperature sensor (sold separately).



Primary and Secondary Inputs for Power Redundancy



● Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations

● Dual 3m input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources



Automatic Transfer Switching



● Dynamic solid-state (TRIAC) automatic transfer switching

● Switches to secondary power source if primary source fails or becomes unstable

● 1–5 ms transfer time ensures uninterrupted operation of connected equipment

● Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source



Multifunction Digital LED Display



● Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factor



Advanced Network Monitoring



● Built-in Ethernet network interface allows remote access for power monitoring, configuration, control and notification via web browser, SSH, telnet or SNMP

● Real-time load/current data with billing-grade accuracy (+/- 1 percent)

● Automated alerts help prevent accidental overloads, power loss and downtime

● Optional temperature sensor (sold separately) monitors temperature and humidity



Broad Communications Compatibility



● Supports HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP



20A Circuit Breakers



● Protect each of 2 single-phase output banks

● Front-panel LED indicates when breaker has tripped



Cord Retention Brackets



● Secures equipment power cords to reduce cable clutter and increase accessibility to connected components



Mounts Horizontally in 2U of Rack Space



● Compatible with EIA-standard 19 in. 4-post racks and rack enclosures



● Single-phase IEC309 32A Blue (2P+E) input and 230V output

● 16 C13 and 2 C19 switched outlets in 2 load banks

● Automatic transfer switching within 1–5 ms

● Ethernet network interface for remote access

● Digital LED display for real-time status monitoring



Package Includes



● PDUMH32HVATNET 7.4kW Single-Phase 230V ATS/Switched PDU

● Rack-mounting brackets

● Cord retention brackets

● Cable ties

● Owner’s manual
AC outlet typesC13 coupler,C19 coupler
AC outlets quantity18 AC outlet(s)
Cable length3 m
Colour of productBlack
Dimensions (WxDxH)444 x 317 x 88 mm
DisplayLCD
Ethernet LAN (RJ-45) ports1
Input frequency50/60 Hz
LED indicatorsY
ManualY
MaterialMetal
Maximum current32 A
Maximum power7700 W
MountingHorizontal
Nominal input voltage200-240 V
Nominal output voltage200-240 V
Operating relative humidity (H-H)5 - 95 %
Package dimensions (WxDxH)424 x 505 x 198 mm
Package weight9200 g
PDU typesSwitched
Power plugIEC309
Rack mounting2u
RoHS complianceY
Storage temperature (T-T)-15 - 50 °C
Supported network protocolsHTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP
TypeSingle-phase
Weight6210 g

PDUMH32HVATNET.pdf

Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount Data Sheet

Download (447.36k)

Similar products

  • Tripp Lite 11.5kW 3-Phase Metered PDU, 240-220V (36-C13 & 9-C19), IEC-309 16A Red, 415-380V Input, 6ft Cord, 0U Vertical
    Tripp Lite 11.5kW 3-Phase Metered PDU,...
  • Tripp Lite 3.84kW Single-Phase Metered PDU, 200/220/230/240V Outlets (32-C13, 6-C19), IEC309 16A Blue 16A, 0U Vertical
    Tripp Lite 3.84kW Single-Phase Metered...
  • Tripp Lite 3.2-3.8kW Single-Phase Metered PDU, 200-240V (8 C13 & 2 C19), C20 / L6-20P Adapter, 12ft Cord, 1U Rack-Mount
    Tripp Lite 3.2-3.8kW Single-Phase Metered...
  • Tripp Lite 3.8kW Single-Phase Metered PDU, 200/220/230/240V Outlets (8 C13, 2 C19) IEC-309 16A Blue, 2.43 m (8-ft.) Cord, 1U
    Tripp Lite 3.8kW Single-Phase Metered PDU,...
  • Tripp Lite 22.2kW 3-Phase Metered PDU, 220/230V, 42 outlets (36 C13, 6 C19), IEC309 32A Red (3P+N+E) 380/400V input, 0U
    Tripp Lite 22.2kW 3-Phase Metered PDU,...

Tripp Lite 7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount

7.4kW Single-Phase ATS/Switched PDU, 230V Outlets (16 C13 & 2 C19), 2 IEC309 32A Blue Cords, 2U Rack-Mount

PDUMH32HVATNET

In Stock

£1,273.61
£1,061.34 Ex VAT.