Excellent
star star star star star
4.7 / 5
1426 Reviews
Roger 
star star star star star
Excellent products and service. Our company have been dealing with Netstore Direct for 11 years now.
Brad 
star star star star star
Easy ordering, well packaged fast delivery.
Guy 
star star star star star
Great selection of products and delivery is always fast.

Categories

Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
  • Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver
The 70-inch (1.77 m) PDUMV32HV 32A 230V 7.4kW Single-Phase Metered Power Distribution Unit features 48 outlets for distributing single-phase AC power to rack-mounted equipment, including computers, routers, switches and servers.



Outlets are arranged in two separate load banks, each with 24 outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank’s real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to

breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and labeled for easy identification.



An ideal PDU for server rooms, network closets and data centers, the PDUMV32HV’s all-metal housing comes ready to mount vertically in your rack using the preinstalled 9 mm buttons or the included hardware. The IEC-309 32A blue input plug with 10-foot (3-Metre) cord connects to your facility’s compatible AC power source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components’ plugs to ensure they remain connected and continuously powered. Use the included ground screw to connect any equipment that requires a chassis ground.

- Ideal for server rooms, network closets and data centers

- Dual load banks with 24 outlets each (4 C19 and 20 C13)

- Dedicated 20A circuit breakers protect output

- IEC-309 32A blue input plug with 10 ft. (3 m) cord

- Ready for immediate toolless 0U installation



- PDUMV32HV 32A 230V 7.4kW Single-Phase Metered PDU

- Plug-lock inserts (8 C20, 40 C13)

- Spare installation buttons, 2.9 mm/4.6 mm

- Ground screw

- Mounting hardware

- Owner’s Manual



- Dual digital ammeters report real-time output current in amps

- Visual monitoring of PDU load level prevents overloading as more equipment is connected

- 32A 230V 7.4kW Metered PDU

- 48 230V outlets—24 per bank (4 C19 and 20 C13)—distribute single-phase power to connected equipment

- Dual load banks with separate 20A circuit breakers and digital ammeters

- Special guards prevent breakers from accidentally tripping

- Each bank is color-coded and labeled for convenient identification

- IEC-309 32A blue input plug with 10 ft. (3 m) cord for easy connection to main power source, generator or protected UPS

- Included plug-lock inserts ensure components remain connected and powered

- Included ground screw for equipment requiring chassis ground

- Ready for immediate toolless 0U installation using preinstalled 9 mm mounting buttons (spare 2.9 mm and 4.6 mm buttons included)

- Nut-and-bolt vertical installation possible with included mounting hardware

- Use included PDUMVROTATEBRKT mounting accessory for installation with outlets facing rear
AC outlet typesC13 coupler,C19 coupler
AC outlets quantity48 AC outlet(s)
Colour of productBlack
Dimensions (WxDxH)245 x 175 x 192.7 mm
MaterialMetal
Maximum current32 A
Mountingvertical
Nominal input voltage230 V
Nominal output voltage200-240 V
Operating altitude0 - 3000 m
Operating relative humidity (H-H)5 - 95 %
Operating temperature (T-T)0 - 50 °C
Package dimensions (WxDxH)68.8 x 64 x 177.8 mm
Package weight5600 g
PDU typesMetered
Power plugIEC309
Rack mounting0U
Storage temperature (T-T)-15 - 60 °C
Weight7700 g

PDUMV32HV.pdf

Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver Data Sheet

Download (488.16k)

Similar products

  • Tripp Lite 11.5kW 3-Phase Metered PDU, 240-220V (36-C13 & 9-C19), IEC-309 16A Red, 415-380V Input, 6ft Cord, 0U Vertical
    Tripp Lite 11.5kW 3-Phase Metered PDU,...
  • Tripp Lite 3.84kW Single-Phase Metered PDU, 200/220/230/240V Outlets (32-C13, 6-C19), IEC309 16A Blue 16A, 0U Vertical
    Tripp Lite 3.84kW Single-Phase Metered...
  • Tripp Lite 3.2-3.8kW Single-Phase Metered PDU, 200-240V (8 C13 & 2 C19), C20 / L6-20P Adapter, 12ft Cord, 1U Rack-Mount
    Tripp Lite 3.2-3.8kW Single-Phase Metered...
  • Tripp Lite 3.8kW Single-Phase Metered PDU, 200/220/230/240V Outlets (8 C13, 2 C19) IEC-309 16A Blue, 2.43 m (8-ft.) Cord, 1U
    Tripp Lite 3.8kW Single-Phase Metered PDU,...
  • Tripp Lite 22.2kW 3-Phase Metered PDU, 220/230V, 42 outlets (36 C13, 6 C19), IEC309 32A Red (3P+N+E) 380/400V input, 0U
    Tripp Lite 22.2kW 3-Phase Metered PDU,...

Tripp Lite 7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Ver

7.4kW Single-Phase Metered PDU, 230V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 3.05 m (10-ft.) Cord, 0U Vertical, 1.77 m (70 in.)

PDUMV32HV

Out of Stock

£531.85
£443.21 Ex VAT.