Quick Transfer RateTransfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.Wrap Around System BypassBreaker maintenance bypass panel to isolate the UPS from the critical load More Info
230V, 16A, 3000VA, 6 x IEC 320 C13 & 1 x IEC 320 C19 Out, 1 x IEC Jumper, 1 x...
APC Maintenance Bypass Panels , Input: 230V , Input Connections: IEC-320 C20 , Cord Length: 8.2 feet ( 2.5 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19,IEC JumpersQuick Transfer RateTransfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.Wrap Around System Bypass(3) Breaker maintenance bypass panel to isolate the UPS from the critical load More Info
Parallel Maintenance Bypass Panel, up to 3 units 10-20kVA 400V Wallmount
AvailabilityDual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.Scalable runtimeAllows additional run time to be quickly added as needed.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedGenerator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS overload condition or fault.Battery... More Info
Parallel Maintenance Bypass Panel, up to 3 units 30-40kVA, 400V Wallmount
Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.Scalable runtimeAllows additional run time to be quickly added as needed.Hot-swappable batteriesEnsures clean, uninterrupted power to protected equipment while batteries are being replacedGenerator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS overload condition or fault.Battery modules connected... More Info
230V, 16A, 3000 VA, IEC Jumpers, 3-wire, 1m Cord, 2.27kg, Black
APC Maintenance Bypass Panels , Input: 230V , Output: 230V , Output Connections: Hard Wire 3-wire (H N + G),IEC JumpersQuick Transfer RateTransfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.Wrap Around System Bypass(3) Breaker maintenance bypass panel to isolate the UPS from the critical load More Info
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A) 17.3kW(24A), 230V, (30) C13 & (12) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC... More Info
WW 10KVA Isolation Transformer
Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.Transformer for Step-down or Step-up or IsolationStep down transformer placed upstream of the UPS to avoid inrush current and saturation eliminating need to oversize transformerHeavy duty designThe Vault Lock’s heavy duty hardened steel construction provides the highest degree of portable tampering protection available on the market. More Info