RACK ATS, 230V, 10A, C14 IN, (12) C13 OUT
APC Rack Automatic Transfer Switch , Input: 230V , Input Connections: IEC-320 C14 , Output Connections: IEC 320 C13.Includes: Documentation CD, Rack Mounting brackets, RS-232 configuration cable, Warranty card. More Info
Rack PDU 2G, Metered, ZeroU, 32A, 230V, (36) C13 & (6) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC... More Info
Rack PDU 2G, Metered, ZeroU, 20A/208V, 16A/230V, (18) C13 & (2) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC... More Info
Rack PDU 2G, Metered, ZeroU, 16A, 230V, (18) C13 & (2) C19, IEC309 Cord
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC... More Info
IT Power Distribution Module 3 Pole 5 Wire 32A IEC309 1040cm
- High Power Density- Low Cost Power Distribution- Meets UL Requirements More Info
IT Power Distribution Module 3 Pole 5 Wire 32A IEC309 500cm
- High Power Density- Low Cost Power Distribution- Meets UL Requirements More Info
Rack PDU 2G, Metered, ZeroU, 22.0kW(32A) 17.3kW(24A), 230V, (30) C13 & (12) C19
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC... More Info
Rack PDU,Basic, 1U, 16A,208&230V, (10)C13 & (2)C19
Description: APC Basic Rack PDU, Input : 120, 208, 230V , Input Connection Type : IEC-320 C20 , Cord Length : 8.2 feet ( 2.5 meters ) , Output : 120, 208, 230V , Output Connections : (10)IEC 320 C13, (2)IEC 320 C19 Features: 19 inch Rack-Mountable, Low Cost Power Distribution, Vertical Mounting Capabilities Includes: Cord Retention Clips, Rack Mounting Brackets, User Manual Output Voltage(s) (main only) - 120, 208, 230 V Maximum Total Current Draw per Phase - 16 A Output Connections - (10)IEC 320 C13; (2)IEC 320 C19 Always on Outlets... More Info
Rack PDU, Basic, 1U, 16A, 208/230V, (12)C13
APC Basic Rack PDU , Input: 208V, 230V , Input Connections: IEC-320 C20 , Cord Length: 8.2 feet ( 2.5 meters ) , Output: 208V, 230V , Output Connections: IEC 320 C13. Includes: Installation guide, Rack Mounting brackets. More Info
Rack PDU,Basic,Zero U,10A,230V, (15)C13
Description - APC Basic Rack PDU, Input : 208, 230V , Input Connection Type : IEC-320 C14 , Cord Length : 6.5 feet ( 1.98 meters ) , Output : 208, 230V , Output Connections : (15)IEC 320 C13 Features - Low Cost Power Distribution, Toolless Mounting Capabilities, Vertical Mounting Capabilities Includes - Installation Guide, Rack Mounting Brackets, Toolless Mounting Kit Output: Output Voltage(s) (main only) - 208, 230 V Maximum Total Current Draw per Phase - 10 A Output Connections - (15)IEC 320 C13 Input: Nominal input voltage -... More Info
Basic Rack PDU AP9572
Rack PDU, Basic, Zero U, 16A, 208/230V, (15) C13. More Info
PDM1332IEC-3P, IT Power Distribution Module 3x1 Pole 3 Wire 32A 3xIEC309...
A touch-safe Power Distribution Module (including circuit breaker, power cord, power connection, and circuit monitoring) that eliminates the need for hot work or shutdowns during expansion of the power distribution system. More Info
Rack PDU, Basic, Zero U, 20A, 120V, (14)5-15
-Toolless mounting capability.-Vertical mounting capability.-Rack-Mountable: Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.-Single input power source: Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.-Wide range of input and output connections: Product family includes a variety of input and output connections... More Info
APC IT Power Distribution Module 3x1 Pole 3 Wire 32A 3xIEC309 480cm, 540cm,...
A touch-safe Power Distribution Module (including circuit breaker, power cord, power connection, and circuit monitoring) that eliminates the need for hot work or shutdowns during expansion of the power distribution system.Includes:Installation guide More Info
Rack PDU, Basic, 1U, 15A, 120V, (10)5-15
-19 inch Rack-Mountable: Supplies redundant AC power to connected equipment. Two AC lines power the unit and if the primary AC power fails, the unit will automatically switch to the alternate power source.-Horizontal mounting capability.-Vertical mounting capability. More Info